Title | Validation of tri-axial accelerometer for the calculation of elevation angles |
Publication Type | Journal Article |
Year of Publication | 2009 |
Authors | Amasay, T, Zodrow, K, Kincl, L, Hess, J, Karduna, A |
Journal | International Journal of Industrial Ergonomics |
Volume | 39 |
Issue | 5 |
Pagination | 783 - 789 |
Date Published | 9/2009 |
Abstract | One of the main issues in occupational studies focusing on musculoskeletal disorders of the upper extremity is how to best quantify workers' exposures to risk factors during a workday. Direct measurement is preferred because it is objective and provides precise measurements. To measure elevationangle exposure of the upper extremity, accelerometers are commonly used. The main problem with the use of accelerometers is the fact that they are sensitive to linear acceleration and can only assess two axes of rotation. In the present study the Virtual Corset, a pager-sized, battery powered, tri-axial linear accelerometer with an integrated data logger, was validated in vitro for the reconstruction of elevationangles under static conditions and angle error prediction under dynamic conditions. For static conditions, the RMS angle error was less than 1°. Under dynamic conditions the elevationangle error was influenced by the radius and angular acceleration. However, the angle error was predicted well with an RMS difference of 3°. It was concluded that the Virtual Corset can be used to accurately predict arm elevationangles under static conditions. Under dynamic conditions, an understanding of the motion being studied and the placement of the Virtual Corset relative to the joint are necessary. |
DOI | 10.1016/j.ergon.2009.03.005 |